Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 390
Filtrar
1.
Trauma Case Rep ; 51: 101018, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38628458

RESUMO

The surgical management of patellar fractures typically yielded satisfactory results; however, in situations involving multifragmented patellar fractures or those affecting the inferior pole, it became imperative to employ alternative osteosynthesis techniques that enhanced stability, enabled early rehabilitation initiation, prevented implant failure, and avoided reduction loss before fracture consolidation. In this context, an unconventional osteosynthesis alternative was presented, utilizing an anatomically designed hook plate originally intended for the fifth metatarsal. This technique was successfully applied in three patients with multifragmentary patellar fractures, allowing stable fixation of small or marginal fragments through the plate's hooks without compromising vascularity. Fracture consolidation was achieved without reduction loss, and owing to its low profile, patient discomfort and irritation were minimized compared to traditional tension band or wiring techniques. This approach suggested the potential to forego early plate removal, thereby contributing to a more effective management of patellar fractures. Level of evidence: IV.

2.
Injury ; 55(6): 111532, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38614015

RESUMO

BACKGROUND: Fixation of sustentaculum tali fractures is important to maintain the biomechanical function of the subtalar joint. A common method of fixation is securing the sustentacular fragment by way of a laterally based locking plate (LP). A medial approach with a single screw (MS) has been proposed as an alternative method of fixation. METHODS: Five pairs of formalin-preserved cadaveric ankles with the subtalar joint and interosseous ligaments intact ("osseous cadavers") and four pairs of fresh-frozen cadaveric ankles with soft-tissue preserved dissected from mid-tibia down ("soft tissue cadavers") were used in the study. The left ankle was randomly assigned to one of the two fixation methods (LP or MS), while the right ankle was the opposite. These same steps for fixation were repeated for six synthetic ankle models. All models were loaded with a body mass of 80 kg. Statistical differences between LP and MS stiffness were determined using a paired t-test in cadavers and un-paired t-tests in synthetic ankles. RESULTS: For osseous cadaveric ankles, LP demonstrated a mean stiffness of 232.95(SD: 59.96) N/mm, while MS was 239.72(SD:131.09) N/mm (p = 0.9293). For soft tissue cadaveric ankles, LP mean stiffness was 133.58(SD:37.84) N/mm, while MS was 134.88(SD:20.75) N/mm (p = 0.9578). For synthetic ankles, LP mean stiffness was 220.40(SD:81.93) N/mm, while MS was 261.50(SD:100.21) N/mm (p = 0.6116). CONCLUSIONS: Across all three models, there was no significant difference between LP and MS methods. Retrospective observational studies are recommended to assess patient outcomes from each of the methods.

3.
Rev Bras Ortop (Sao Paulo) ; 59(1): e107-e118, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38524703

RESUMO

Objective: The present study compared the difference in load and pressure distribution behavior of the blade plate and locked plate for varus osteotomy of the proximal femur per the finite element method. Methods: Modeling was performed by scanning a medium-sized left femur with medial valgus deformity made of polyurethane. Results: The stiffness of the locked plate is higher compared with that of the blade plate. However, this difference was not significant. In addition, the locked plate has proximal locking screws to ensure that the bending moments on the screws are smaller during loading. Conclusion: In summary, both plates are well-established and effective. However, the study using the finite element method plays a fundamental role in understanding the load and pressure distribution of the implant. Moreover, it opens up new possibilities for further studies, including surgical proposals and customized implant materials.

4.
Cureus ; 16(1): e53120, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38420078

RESUMO

Extension of existing spinal fusions may necessitate the removal of or linkage to prior constructs. Knowledge of previously placed instrumentation is critical to success in these revision scenarios. The Luque spinal instrumentation system, developed in the late 1980s, is a legacy pedicle screw and plate system that may be encountered during revision operations today. A 67-year-old male with a remote history of L4-S1 fusion with Luque instrumentation presented with bilateral lower extremity neurogenic claudication due to adjacent segment disease at L3-4. Decompression and extension of fusion to the L3-4 level were performed using minimally invasive techniques. Of note, posterior instrumentation was extended by removing prior L4 pedicle screws with a 7 mm female hexagonal driver through tubular retractors, leaving the Luque plates in place, placing modern pedicle screws at L4 (through the plates) and L3, and linking these with standard rods. The surgery and post-operative course were uncomplicated, and the patient experienced complete resolution of his pre-operative claudication symptoms. Extension of prior Luque plate instrumented fusion can be accomplished minimally invasively without removing the plates themselves, resulting in greater operative efficiency and less surgical morbidity.

5.
Adv Biomed Res ; 12: 206, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38073722

RESUMO

Background: Tibial plateau fractures have become more frequent in recent years. The most prevalent Schatzker classification is type II, which is a lateral tibial plateau fracture with depression. Our null hypothesis was that the 3.5 T-plate and the 4.5 T-plate have no difference in the management of patients with Schatzker type II tibial plateau fractures. Materials and Methods: The current study is a clinical trial that was conducted on patients with tibial plateau fractures. The Knee Society Score (KSS) was this study's main outcome. Tourniquet time (TT) and patient quality of life using the 36-item Short Form Survey Instrument (SF-36) were secondary goals of the outcomes measurement study. VAS measured pain. Among 176 patients, 89 and 87 of cases underwent surgical treatment with 3.5-mm (group A) and 4.5-mm (group B) T-plate, respectively. The data were entered into SPSS software (version 25, IBM Corporation, Armonk, NY) and analyzed. Results: In our study, we evaluated 176 patients with a mean age of 34.8 ± 15.2 years. Functional and clinical KSS scores were similar between the two groups throughout follow-up (P > 0.05). Regarding the other variables of VAS, TT, SF-36 physical function, and SF-36 mental health, no significant difference was observed between the two groups, and the two groups had similar averages in terms of these indicators (P > 0.05). Conclusion: According to the results, both plates had the appropriate functional outcomes in patients with split depression tibial plateau fracture.

6.
Rev Bras Ortop (Sao Paulo) ; 58(6): e896-e904, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38077774

RESUMO

Objective Various modalities have been suggested to manage mallet fractures; however, inappropriate treatment can lead to extension lag, a swan neck deformity, or arthritis of the distal interphalangeal joint (DIPJ). The current study aimed to evaluate the results (functional, radiological, and complications) of open reduction and internal fixation (ORIF) of mallet fractures using low-cost hook plates fabricated from low-profile titanium mini plates. Methods A prospective case series of 17 consecutive patients (average age of 32.3 years) with mallet fractures (six were Wehbe Type IB and 11 were Wehbe Type IIB). Eleven (64.7%) were males. The affected hand was dominant in all patients, and the affected digit was the index in 6 (35.3%), the ring in 5 (29.4%), the small in 3 (17.65%), and the middle in 3 (17.65%) patients. The same fellowship-trained hand surgeon performed all surgeries. Results The average operative time was 37.65 minutes. After an average follow-up of 10.94 months (range 6-27), the average DIPJ motion was 50° ° (range 20°-70°), the extensor lag was noted in 4 (23.5%) patients, and complications were reported in 6 (35.29%) patients. According to Crawford criteria, 6 (35.3%) patients achieved excellent results, 7 (41.2%) achieved good results, and 4 (23.5%) achieved fair results. Conclusion The modified hook plate technique for fixation of mallet fractures is a beneficial, economical, yet demanding technique that adequately provides stable fixation to allow early DIPJ motion with acceptable functional outcomes.

7.
Odontol. vital ; (39): 27-39, jul.-dic. 2023. tab, graf
Artigo em Espanhol | LILACS, SaludCR | ID: biblio-1550585

RESUMO

RESUMEN Introducción: Los tratamientos para fracturas de órbita se basan en la corrección del defecto de las lesiones orbitarias de tipo blow in y blow out (o de estallido), mediante diversas placas y mallas biocompatibles con el organismo, dándose una cicatrización de primera generación evitando un callo óseo y una fijación más rígida. Para el diagnóstico de este tipo de lesiones tenemos inflamación periorbitaria, enoftalmos, diplopía, equimosis, hemorragia subconjuntival. Existen diversos materiales reconstructivos siendo estos compuestos por distintas materias primas, como son los aloplásticos y autógenos; donde encontramos varios tipos como placas de titanio y las placas reabsorbibles siendo estas las más comunes y usadas actualmente, por su bajo estímulo a reabsorciones óseas y evitando efectos secundarios a largo plazo. Estas placas presentan diversos grados de ductilidad y resistencia. Se informó sobre varias complicaciones según el tipo de placas como es la cicatrización, las cirugías postquirúrgicas en caso de placas de titanio, etc. El objetivo de esta revisión es la evaluación de la eficacia las placas reabsorbibles versus placas de titanio en fracturas de órbita. Materiales y métodos: La investigación es de carácter documental, descriptivo y no experimental. En el cual se emplea una metodología de identificación e inclusión de artículos científicos tipo prisma. Resultados y conclusiones: Se verificaron las ventajas y desventajas tanto de las placas reabsorbibles como las de titanio siendo estas similares en la biocompatibilidad con el organismo humano, así como también varias diferencias como el soporte, fuerzas, resistencia de estas, concluyendo que es debatible el material ideal para tratar fracturas de órbita. Se seleccionaron artículos tomando en cuenta el título y objetivos; considerando estudios comparativos, revisiones sistemáticas, revisiones de literatura, los cuales comprendían criterios con respecto a fracturas de órbita y tratamientos quirúrgicos. La búsqueda arrojó 55 artículos en PubMed, 65 en Google, 4 en Scielo y 29 en Science direct, de los cuales se excluyeron libros, monografías, estudios experimentales, dando como resultado 21 artículos para el desarrollo de esta revisión bibliográfica. Y que fueron leídos y analizados en su totalidad, estudiando los objetivos, metodología y conclusión de cada uno de ellos para la posterior comparación.


ABSTRACT Introduction: Treatments for orbit fractures are based on the correction of the defect of blow in and blow out orbital injuries, by means of various plates and meshes biocompatible with the organism, giving a first-generation healing avoiding a bony callus and a more rigid fixation. For the diagnosis of this type of lesions we have periorbital inflammation, enophthalmos, diplopia, ecchymosis, subconjunctival hemorrhage. There are several reconstructive materials being these composed of different raw materials, such as alloplastic and autogenous, where we find several types such as titanium plates and resorbable plates being these the most common and currently used, for its low stimulus to bone resorption and avoiding long-term side effects. These plates have different degrees of ductility and resistance. Several complications have been reported depending on the type of plates, such as scarring, post-surgical surgeries in the case of titanium plates, etc. The objective of this review is to evaluate the efficacy of resorbable versus titanium plates in orbital fractures. Materials and methods: This research are a documentary, descriptive and non-experimental nature. A prism-type methodology of identification and inclusion of scientific articles was used. Results and conclusions: The advantages and disadvantages of both resorbable and titanium plates were verified, being these similar in biocompatibility with the human organism, as well as several differences such as support, forces, resistance of the same, concluding that it is debatable. The ideal material to treat orbital fractures. Articles were selected considering the title and objectives; considering comparative studies, systematic reviews, literature reviews, which included criteria regarding orbital fractures and surgical treatments. The search yielded 55 articles in PubMed, 65 in Google, 4 in Scielo and 29 in Science direct, from which books, monographs, experimental studies were excluded, resulting in 21 articles for the development of this bibliographic review. The 21 articles were read and analyzed in their entirety, studying the objectives, methodology and conclusion of each one of them for subsequent comparison.


Assuntos
Humanos , Órbita/lesões , Placas Ósseas , Titânio , Materiais Biocompatíveis/uso terapêutico , Fraturas Ósseas/cirurgia
8.
Clin Orthop Surg ; 15(5): 843-852, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37811514

RESUMO

Background: Surgery of the medial end of the clavicle remains a challenge for orthopedic surgeons. Moreover, there is no standard surgical procedure for treating displaced fractures or dislocation of the medial clavicle. Thus, the present study aimed to evaluate the safety and efficacy of using a hook plate for treating medial-end clavicular fractures and present functional outcomes. Methods: We retrospectively investigated 18 patients who underwent surgery with a hook plate from July 2016 to December 2021. There were 14 men and 4 women with a mean age of 57.4 years. Fracture union was assessed at follow-up by computed tomography (CT). Other outcome parameters were complications, including implant failure, infection, nonunion, osteolysis of sternal manubrium, and migration of the hook portion. Range of motion (ROM), visual analog scale (VAS), Quick Disabilities of the Arm, Shoulder and Hand (Quick DASH), and American Shoulder and Elbow Society (ASES) scores were evaluated 6 months postoperatively and at the last follow-up. Results: The mean operation time was 43.8 minutes (range, 35-50 minutes) and the mean follow-up was 22.8 months (range, 12-42 months). Bone union was confirmed in all cases. The mean union time was 6.2 months (range, 6-7 months). Implant removal was performed routinely according to the clinical course in 17 cases. The mean implant removal time was 10.0 months (range, 6-14 months). Clinical and functional outcomes measured at the last follow-up were significantly improved compared to those at 6 months postoperatively (p < 0.05). Regarding complications, there were 6 cases (33.3%) of osteolysis of the sternal manubrium. Although the anteroposterior length of the manubrium and hook depth showed significant differences between the non-osteolysis group and the osteolysis group (p = 0.024), ROM, VAS, Quick DASH, and ASES scores were not significantly different between the two groups (all p > 0.05). Conclusions: Clavicle hook plating can be a safe and effective method that can be easily applied with good outcomes if it is used with appropriate surgical planning and technique for medial-end clavicle fracture. CT scans are useful for preoperative planning and postoperative evaluation of bone union or complications.


Assuntos
Fraturas Ósseas , Osteólise , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Resultado do Tratamento , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Placas Ósseas
9.
J Dent ; 137: 104650, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37544353

RESUMO

OBJECTIVES: Surgeons often encounter challenges when treating maxillofacial fractures using conventional methods that involve trimming or bending ready-made titanium plates for open reduction and internal fixation (ORIF) since it can be time-consuming, imprecise, and inconvenient. This retrospective case series aimed to introduce a novel bone reduction method that utilizes virtual planning, patient-specific surgical guides, and titanium plates. METHODS: Seven patients with mandibular symphysis or subcondylar fractures resulting from facial trauma underwent cone-beam computed tomography (CBCT) or facial CT scans, and their medical histories were documented. Virtual surgery was conducted based on three-dimensional (3D) stereolithography images derived from CT scans using the FaceGide software (MegaGen, Daegu, Korea). ORIF was performed using patient-specific surgical guides and plates that were designed, printed, and milled. Radiographic, clinical, and occlusal evaluations were conducted at two weeks and six weeks postoperatively. Subsequently, 3D images from virtual surgery and postoperative CT scans were compared. RESULTS: The comparison of 3D virtual surgery and postoperative images revealed minimal surface differences of less than 1 mm. T-scan evaluations indicated that there were no statistically significant differences between the two- and six-week postoperative assessments. Favorable clinical outcomes were observed. CONCLUSION: This novel method demonstrated stable outcomes in terms of occlusion and healing, with no notable complications. Consequently, this approach may serve as a viable alternative to conventional methods. CLINICAL SIGNIFICANCE: Facial fracture surgery that utilizes patient-specific surgical guides and plates within a digital workflow can facilitate meticulous surgical planning, reducing the risk of complications and minimizing operation time.


Assuntos
Fixação Interna de Fraturas , Fraturas Ósseas , Humanos , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Titânio , Fraturas Ósseas/cirurgia , Tomografia Computadorizada por Raios X
10.
J Mech Behav Biomed Mater ; 143: 105929, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37263171

RESUMO

The metallic biomaterials have been proclaimed to exhibit stress shielding with discharge of toxic ions, leading to polymeric implants attracting interest in 3D Printing domain. In this study, Poly Lactic Acid based 336 bone plates are fabricated using Fused Filament Fabrication with printing parameters being varied. Polydopamine, being biocompatible, is deposited on fabricated bone plates at varying submersion time, shaker speed and coating solutions concentration. The study involves witnessing the effect of printing and coating parameters on biological behavior of bone plates upon preservation in Simulated Body Fluid and Hank's Balanced Salt Solution. The findings propose the close relation of degradation with apatite growth. The highest degradation rate with significant reduction in mechanical characteristics are shown by uncoated bone plates. These bone plates have porous structure at 20% infill density, 0.5 mm layer height, 0.4 mm wall thickness and 100 mm/s print speed which could result in complete degradation with partial healing of bone fracture. The study suggests the preservation of bone plates coated at 120 h' submersion time and 120 RPM shaker speed in 3 mg/ml concentrated solution which showed lower apatite formation. Thus, the coating would slow down degradation of PLA bone plates, resulting in complete healing of bone fracture.


Assuntos
Placas Ósseas , Fraturas Ósseas , Humanos , Poliésteres/química , Apatitas/química , Ácido Láctico/química , Impressão Tridimensional , Atenção à Saúde
11.
Br J Oral Maxillofac Surg ; 61(5): 362-367, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37263889

RESUMO

The aim of this study was to comparatively analyse osseointegration after the implantation of self-tapping screws (STS) and self-drilling screws (SDS). Thus, 24 four-month-old male Wistar rats, received SDS and STS screws in their left and right tibias, respectively. Sample collection was performed immediately at 0 hours (0h), two, seven, and 21 days after implantation (2d, 7d, 21d). Samples from immediately and 21 days after were analysed by micro computed tomography (MicroCT). All time points were evaluated by histology (Haematoxylin and Eoisin and Goldner's Trichrome) and immunohistochemistry for tartrate-acid resistant phosphatase positive (TRAP+) osteoclasts. MicroCT images revealed an intimate contact between bone and each type of screw at 0h. However, SDS group presented decreased bone volume (BV, mm3) at 21 days in comparison with STS. Both SDS and STS post implantation presented areas of suitable new bone formation surrounding screw threads from seven days, and inflammation decreased from two to 21 days. Also, TRAP+ osteoclasts were mainly identified at seven days in both STS and SDS groups, particularly surrounding areas of pressure, with significant differences between groups. In conclusion, differences in shape and insertion technique for SDS and STS screws did not affect immediate and late inflammatory and bone healing response post implantation in this animal model. Both osteosynthesis screws allowed satisfactory post-surgical outcomes.


Assuntos
Parafusos Ósseos , Osso e Ossos , Animais , Ratos , Masculino , Ratos Wistar , Microtomografia por Raio-X , Fixação Interna de Fraturas
12.
Rev Bras Ortop (Sao Paulo) ; 58(2): 326-330, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37252299

RESUMO

Objective Medial open wedge high tibial osteotomy (MOWHTO) significantly relieves pain in the medial joint line in medial compartment osteoarthritis of the knee. But some patients complain of pain over the pes anserinus even 1 year after the osteotomy, which may require implant removal for relief. This study aims to define the implant removal rate after MOWHTO due to pain over the pes anserinus. Methods One hundred and three knees of 72 patients who underwent MOWHTO for medial compartment osteoarthritis between 2010 and 2018 were enrolled in the study. Knee injury and osteoarthritis outcome score (KOOS), Oxford knee score (OKS), and visual analogue score (VAS) were assessed for pain in the medial knee joint line (VAS-MJ) preoperatively, 12 months postoperatively, and yearly thereafter; adding VAS for pain over the pes anserinus (VAS-PA). Patients with VAS-PA ≥ 40 and adequate bony consolidation after 12 months were recommended implant removal. Results Thirty-three (45.8%) of the patients were male and 39 (54.2%) were female. The mean age was 49.4 ± 8.0 and the mean body mass index was 27.0 ± 2.9. The Tomofix medial tibial plate-screw system (DePuy Synthes, Raynham, MA, USA) was used in all cases. Three (2.8%) cases with delayed union requiring revision were excluded. The KOOS, OKS, and VAS-MJ significantly improved 12 months after MOWHTO. The mean VAS-PA was 38.3 ± 23.9. Implant removal for pain relief was needed in 65 (63.1%) of the103 knees. The mean VAS-PA decreased to 4.5 ± 5.6 3 months after implant removal ( p < 0.0001). Conclusion Over 60% of the patients may need implant removal to relieve pain over the pes anserinus after MOWHTO. Candidates for MOWHTO should be informed about this complication and its solution.

13.
Front Surg ; 10: 1170760, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37228760

RESUMO

We reported 2 cases of patellar tendon rupture at the lower pole of the patella. For patellar tendon rupture, simple suture fixation has been proved to be inadequate in strength. Our center uses custom-made anchor-like plate and suture to treat proximal patellar fracture. The fixation strength is reliable, no additional bone tunnel is required, and the fixation of the lower patellar fracture can be achieved at the same time. After the operation, the patient starts functional exercise of the knee joint at an early stage, The function of the knee joint of the patient recovered well after 1 year, without other complications.

14.
Acta Ortop Bras ; 31(spe1): e252977, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37082159

RESUMO

Objectives: This study aimed to compare the functional and radiological results of patients who had intra-articular comminuted distal radius fractures and were operated on with external fixation percutaneous pinning or the volar-dorsal combined plate osteosynthesis. Methods: In this study, 49 patients operated on and followed up for the comminuted distal radius fractures between May 2015 and January 2019 were retrospectively evaluated. The surgical outcomes of the patients, who were operated on with combined dorsal-volar plate osteosynthesis or external fixation percutaneous pinning, were compared in this study. Functional and radiological scores were evaluated and analyzed statistically. Results: There was no statistical difference between external fixation and volar-dorsal combined plate groups regarding the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire, the Visual Analog Scale (VAS), the Mayo scoring system, range of motion, and grip strength values. Discussion: Although the combined volar-dorsal plate osteosynthesis technique had a longer operation time and a more complicated surgical procedure, the combined volar-dorsal plate osteosynthesis had lower complication rates and permitted early mobilization. The combined volar-dorsal plate osteosynthesis could be an alternative to external fixation percutaneous pinning. Level of Evidence III, Therapeutic Studies Investigating the Results of Treatment.


Objetivo: O objetivo deste estudo foi comparar os resultados funcionais e radiológicos de pacientes portadores de fraturas intra-articulares cominutivas do rádio distal, operados com fixação externa percutânea ou com osteossíntese volar-dorsal de placa combinada. Método: Foram avaliados 49 pacientes operados e acompanhados por fraturas cominutivas distais do rádio entre maio de 2015 e janeiro de 2019 retrospectivamente. Os resultados cirúrgicos dos pacientes operados com osteossíntese de placa volar-dorsal combinada ou fixação externa percutânea foram comparados. Os escores funcionais e radiológicos foram avaliados e analisados estatisticamente. Resultados: Não houve diferença estatística entre os grupos de fixação externa e placa combinada volar-dorsal em relação ao questionário Deficiências do braço, ombro e mão (DASH), à Escala Visual Analógica (VAS), ao sistema de pontuação Mayo, à amplitude de movimento ou à avaliação de força de preensão. Conclusão: Embora a técnica combinada de osteossíntese da placa volar-dorsal tenha um tempo cirúrgico mais longo e procedimento mais complicado, a osteossíntese combinada da placa volar-dorsal apresentou menores taxas de complicações, permitindo a mobilização precoce. A osteossíntese combinada da placa volar-dorsal pode ser uma alternativa à fixação externa percutânea. Nível de Evidência III, Estudos terapêuticos ­ Investigação dos resultados do tratamento.

15.
Rev. bras. ortop ; 58(2): 326-330, Mar.-Apr. 2023. tab
Artigo em Inglês | LILACS | ID: biblio-1449798

RESUMO

Abstract Objective Medial open wedge high tibial osteotomy (MOWHTO) significantly relieves pain in the medial joint line in medial compartment osteoarthritis of the knee. But some patients complain of pain over the pes anserinus even 1 year after the osteotomy, which may require implant removal for relief. This study aims to define the implant removal rate after MOWHTO due to pain over the pes anserinus. Methods One hundred and three knees of 72 patients who underwent MOWHTO for medial compartment osteoarthritis between 2010 and 2018 were enrolled in the study. Knee injury and osteoarthritis outcome score (KOOS), Oxford knee score (OKS), and visual analogue score (VAS) were assessed for pain in the medial knee joint line (VAS-MJ) preoperatively, 12 months postoperatively, and yearly thereafter; adding VAS for pain over the pes anserinus (VAS-PA). Patients with VAS-PA ≥ 40 and adequate bony consolidation after 12 months were recommended implant removal. Results Thirty-three (45.8%) of the patients were male and 39 (54.2%) were female. The mean age was 49.4 ± 8.0 and the mean body mass index was 27.0 ± 2.9. The Tomofix medial tibial plate-screw system (DePuy Synthes, Raynham, MA, USA) was used in all cases. Three (2.8%) cases with delayed union requiring revision were excluded. The KOOS, OKS, and VAS-MJ significantly improved 12 months after MOWHTO. The mean VAS-PA was 38.3 ± 23.9. Implant removal for pain relief was needed in 65 (63.1%) of the103 knees. The mean VAS-PA decreased to 4.5 ± 5.6 3 months after implant removal (p < 0.0001). Conclusion Over 60% of the patients may need implant removal to relieve pain over the pes anserinus after MOWHTO. Candidates for MOWHTO should be informed about this complication and its solution.


Resumo Objetivo A osteotomia tibial alta com cunha de abertura medial (MOWHTO, do inglês medial open wedge high tibial osteotomy) alivia de forma significativa a dor na linha articular medial em casos de osteoartrite do compartimento medial do joelho. Alguns pacientes, porém, se queixam de dor nos tendões dos músculos sartório, grácil e semitendinoso (pata de ganso) mesmo 1 ano após a osteotomia, o que pode exigir a remoção do implante. Este estudo define a taxa de remoção do implante após a MOWHTO devido à dor nos tendões dos músculos sartório, grácil e semitendinoso. Métodos Cento e três joelhos de 72 pacientes submetidos à MOWHTO para tratamento da osteoartrite do compartimento medial entre 2010 e 2018 foram incluídos no estudo. A pontuação de desfecho de lesão no joelho e osteoartrite (KOOS, do inglês Knee Injury and Osteoarthritis Outcome Score), a pontuação dejoelho de Oxford (OKS, do inglês Oxford Knee Score) e a escala visual analógica (EVA) de dor na linha articular medial do joelho (EVA-MJ) foram avaliados antes da cirurgia. A EVA nos tendões dos músculos sartório, grácil e semitendinoso (EVA-PA) foi adicionada a essas avaliações, também realizadas 12 meses após o procedimento e, a seguir, anualmente. A remoção do implante foi recomendada em pacientes com EVA-PA ≥ 40 e consolidação óssea adequada em 12 meses. Resultados Trinta e três (45,8%) pacientes eram homens e 39 (54,2%), mulheres. A média de idade foi de 49,4 ±8,0, e o índice de massa corpórea (IMC) médio foi de 27,0 ± 2,9. O sistema placa-parafuso tibial medial Tomofix (DePuy Synthes, Raynham, MA, EUA) foi utilizado em todos os casos. Três (2,8%) casos foram excluídos devido ao retardo de consolidação e à necessidade de revisão. Os resultados nas escalas KOOS, OKS e EVA-MJ melhoraram significativamente 12 meses após a MOWHTO. A EVA-PA média foi de 38,3 ± 23,9. A remoção do implante para alívio da dor foi necessária em 65 (63,1%) dos 103 joelhos. Três meses após a remoção do implante, a EVA-PA média diminuiu para 4,5 ± 5,6 (p < 0,0001). Conclusão A remoção do implante pode ser necessária em mais de 60% dos pacientes para alívio da dor nos tendões dos músculos sartório, grácil e semitendinoso após a MOWHTO. Os candidatos à MOWHTO devem ser informados sobre esta complicação e sua resolução.


Assuntos
Humanos , Osteotomia , Infecção da Ferida Cirúrgica , Tíbia/cirurgia , Placas Ósseas , Transplante Ósseo , Remoção de Dispositivo
16.
Arch Orthop Trauma Surg ; 143(4): 2247-2253, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36182974

RESUMO

INTRODUCTION: Scaphoid fractures represent 5-10% of nonunion rate and the treatment options consist of an open reduction with correction of deformity, restoration of the scaphoid length with autologous wedge grafting and fixation. However, there is still no consensus in the literature on the best fixation method. Therefore, the purpose of the study is to compare plate fixation and screw fixation in treating scaphoid nonunion with humpback deformity and carpal instability. METHODS: Prospective, non-randomised study comparing the treatment of two groups of patients with scaphoid nonunion. A total of 19 patients were included in the study, the first ten patients were included in group 1 (plate fixation), subsequently nine patients were included in group 2 (screw fixation). The nonunion duration was longer than 6 months and patients did not present type III Scaphoid Nonunion Advanced Collapse (SNAC). Clinical evaluations included pain intensity, range of motion, grip strength, pinch test and functional scales Disabilities of the Arm, Shoulder and Hand (DASH) and Mayo Wrist Score. Radiographic evaluations consisted of radiographs of both wrists in AP, AP with ulnar deviation, lateral and oblique views. Patients further underwent a tomography of the affected wrist for bone deformity, carpal collapse and later consolidation evaluation. RESULTS: According to post-operative measurements, group 1 showed a significant improvement in the scapholunate angle (p = 0.011) and in the intrascaphoid angle (p = 0.002). Group 2 only showed an improvement in the scapholunate angle (p = 0.011). All patients in group 1 achieved consolidation in 8 weeks, while group 2 patients had a slower consolidation, with a mean of 14 weeks and standard deviation (SD) of 4.2, with statistical significance (p = 0.006). CONCLUSION: Our prospective study, despite the limitations, contributes to the literature for demonstrating a better fixation using plate, with a better correction of humpback deformity and Dorsal Intercalated Segment Instability (DISI) and a faster consolidation. LEVEL OF EVIDENCE: II, therapeutics studies; prospective comparative study.


Assuntos
Osso Escafoide , Extremidade Superior , Humanos , Estudos Prospectivos , Osso Escafoide/diagnóstico por imagem , Osso Escafoide/cirurgia , Punho , Parafusos Ósseos
17.
Acta ortop. bras ; 31(spe1): e252977, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1429579

RESUMO

ABSTRACT Objectives: This study aimed to compare the functional and radiological results of patients who had intra-articular comminuted distal radius fractures and were operated on with external fixation percutaneous pinning or the volar-dorsal combined plate osteosynthesis. Methods: In this study, 49 patients operated on and followed up for the comminuted distal radius fractures between May 2015 and January 2019 were retrospectively evaluated. The surgical outcomes of the patients, who were operated on with combined dorsal-volar plate osteosynthesis or external fixation percutaneous pinning, were compared in this study. Functional and radiological scores were evaluated and analyzed statistically. Results: There was no statistical difference between external fixation and volar-dorsal combined plate groups regarding the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire, the Visual Analog Scale (VAS), the Mayo scoring system, range of motion, and grip strength values. Discussion: Although the combined volar-dorsal plate osteosynthesis technique had a longer operation time and a more complicated surgical procedure, the combined volar-dorsal plate osteosynthesis had lower complication rates and permitted early mobilization. The combined volar-dorsal plate osteosynthesis could be an alternative to external fixation percutaneous pinning. Level of Evidence III, Therapeutic Studies Investigating the Results of Treatment.


RESUMO Objetivo: O objetivo deste estudo foi comparar os resultados funcionais e radiológicos de pacientes portadores de fraturas intra-articulares cominutivas do rádio distal, operados com fixação externa percutânea ou com osteossíntese volar-dorsal de placa combinada. Método: Foram avaliados 49 pacientes operados e acompanhados por fraturas cominutivas distais do rádio entre maio de 2015 e janeiro de 2019 retrospectivamente. Os resultados cirúrgicos dos pacientes operados com osteossíntese de placa volar-dorsal combinada ou fixação externa percutânea foram comparados. Os escores funcionais e radiológicos foram avaliados e analisados estatisticamente. Resultados: Não houve diferença estatística entre os grupos de fixação externa e placa combinada volar-dorsal em relação ao questionário Deficiências do braço, ombro e mão (DASH), à Escala Visual Analógica (VAS), ao sistema de pontuação Mayo, à amplitude de movimento ou à avaliação de força de preensão. Conclusão: Embora a técnica combinada de osteossíntese da placa volar-dorsal tenha um tempo cirúrgico mais longo e procedimento mais complicado, a osteossíntese combinada da placa volar-dorsal apresentou menores taxas de complicações, permitindo a mobilização precoce. A osteossíntese combinada da placa volar-dorsal pode ser uma alternativa à fixação externa percutânea. Nível de Evidência III, Estudos terapêuticos - Investigação dos resultados do tratamento.

18.
Rev. bras. ortop ; 58(6): 896-904, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1535608

RESUMO

Abstract Objective Various modalities have been suggested to manage mallet fractures; however, inappropriate treatment can lead to extension lag, a swan neck deformity, or arthritis of the distal interphalangeal joint (DIPJ). The current study aimed to evaluate the results (functional, radiological, and complications) of open reduction and internal fixation (ORIF) of mallet fractures using low-cost hook plates fabricated from low-profile titanium mini plates. Methods A prospective case series of 17 consecutive patients (average age of 32.3 years) with mallet fractures (six were Wehbe Type IB and 11 were Wehbe Type MB). Eleven (64.7%) were males. The affected hand was dominant in all patients, and the affected digit was the index in 6 (35.3%), the ring in 5 (29.4%), the small in 3 (17.65%), and the middle in 3 (17.65%) patients. The same fellowship-trained hand surgeon performed all surgeries. Results The average operative time was 37.65 minutes. After an average follow-up of 10.94 months (range 6-27), the average DIPJ motion was 50º º (range 20º-70º), the extensor lag was noted in 4 (23.5%) patients, and complications were reported in 6 (35.29%) patients. According to Crawford criteria, 6 (35.3%) patients achieved excellent results, 7 (41.2%) achieved good results, and 4 (23.5%) achieved fair results. Conclusion The modified hook plate technique for fixation of mallet fractures is a beneficiai, economical, yet demanding technique that adequately provides stable fixation to allow early DIPJ motion with acceptable functional outcomes.


Resumo Objetivo Diversas modalidades têm sido sugeridas para o tratamento de fraturas em martelo; no entanto, o tratamento inadequado pode causar retardo de extensão, deformidade em pescoço de cisne ou artrite da articulação interfalangiana distal (AIFD). Este estudo teve como objetivo avaliar os desfechos (funcionais, radiológicos e complicações) da redução aberta e fixação interna (RAFI) das fraturas em martelo com placas de gancho de baixo custo fabricadas com mini placas de titânio de baixo perfil. Métodos Série de casos prospectivos de 17 pacientes consecutivos (idade média de 32,3 anos) com fraturas em martelo (seis do tipo IB e 11 do tipo IIB de Wehbe). Onze (64,7%) pacientes eram do sexo masculino. A mão acometida era a dominante em todos os pacientes, com acometimento do dedo indicador em seis (35,3%), anelar em cinco (29,4%), mínimo em três (17,65%) e médio em três (17,65%) pacientes. O mesmo cirurgião de mão experiente realizou todas as cirurgias. Resultados O tempo operatório médio foi de 37,65 minutos. Após um acompanhamento médio de 10,94 meses (intervalo de 6 a 27), observou-se movimento médio da AIFD de 50º (intervalo de 20º a 70º), retardo de extensão em quatro (23,5%) pacientes e complicações em seis (35,29%) pacientes. De acordo com os critérios de Crawford, os desfechos foram excelentes em seis (35,3%), bons em sete (41,2%) e regulares em quatro (23,5%) pacientes. Conclusão A técnica da placa de gancho modificada para fixação de fraturas em martelo é benéfica e econômica, mas exigente; permite fixação estável e adequada para permitir a movimentação precoce da AIFD com desfechos funcionais aceitáveis.


Assuntos
Humanos , Placas Ósseas , Fraturas Ósseas , Traumatismos dos Dedos , Articulações dos Dedos , Fixação Interna de Fraturas
19.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-992772

RESUMO

Objective:To investigate the efficacy of Masquelet induced membrane technique combined with an external locking plate in the treatment of infectious bone defects of the tibia.Methods:A retrospective study was conducted to analyze the data of 32 patients with infectious bone defects of the tibia who had been treated by Masquelet induced membrane technique combined with an external locking plate at Department of Orthopaedic Surgery, The Fourth Hospital of Wuhan from January 2011 to January 2021. There were 22 males and 10 females, with an age of (43.2±13.1) years. The length of bone defects was (5.1±1.3) cm. By the Cierny-Mader classification, there were 12 cases of type Ⅲ and 20 cases of type Ⅳ. The defects were located at the proximal tibia in 11 cases, at the middle tibia in 12, and at the distal tibia in 9. At the last follow-up, the lower limb function was evaluated by the Paley scale, and the quality of life by the 36-Item Short Form Health Survey (SF-36).Results:All the 32 patients were followed up for (21.2±5.7) months. Normal healing was achieved in 30 cases but delayed healing occurred in 2 cases. The external plate and screws were removed at (23.1±4.6) weeks after operation. There was no infection in the original surgical incision or no injury to the nerve, blood vessel or tendon after operation, but nail tract infection occurred more or less in 3 cases. According to the Paley scale at the last follow-up, the lower limb function was evaluated as excellent in 22 cases, as good in 8, and as fair in 2, giving an excellent and good rate of 93.75% (30/32). The SF-36 quality of life score was (88.9±3.8) points.Conclusion:In the treatment of infectious bone defects of the tibia, Masquelet induced membrane technique combined with an external locking plate can achieve satisfactory clinical outcomes due to its effective control of infection, reduction in delayed healing, good stability and good patient tolerance.

20.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-992739

RESUMO

Objective:To evaluate our self-designed pubic symphysis orthotic compression anatomic plate (PSOCAP) in the treatment of fractures and dislocations around the pubic symphysis.Methods:A retrospective study was conducted to analyze the 16 patients with fracture or dislocation around the pubic symphysis who had been treated by our self-designed PSOCAP at Department of Traumatic Surgery, Center for Orthopaedic Surgery, The Third Hospital Affiliated to Southern Medical University from January 2021 to June 2022. There were 8 males and 8 females with an age of (41±19) years. According to the Tile classification for pelvic fractures, there were 3 cases of type B1, 2 cases of type B3, 1 case of type C1.2, 4 cases of type C1.3, 3 cases of type C2, and 3 cases of type C3. There were 8 cases of pubic symphysis separation and 8 fractures of the pubic ramus (2 ones at Nakatani zone Ⅰ and 6 ones at Nakatani zone Ⅱ). Time from injury to surgery was 16 (11, 53) days, ranging from 4 to 348 days. The fractures or dislocations around the pubic symphysis were exposed by the modified Stoppa approach, reduced with the assistance of PSOCAP and fixated with PSOCAP; the posterior pelvic ring was reduced and fixated by corresponding surgical methods. Recorded were the surgical time, intraoperative bleeding, postoperative quality of fracture reduction, surgical complications, and functional recovery at the last follow-up concerning the pelvic anterior ring.Results:Surgery went on successfully in the 16 patients. Their surgical time was (58±15) min, ranging from 40 to 90 min, and their intraoperative bleeding 85 (63, 150) mL, ranging from 50 to 250 mL. According to the Matta scoring, the fracture reduction was evaluated as excellent in 10 cases, as good in 3 cases and as fair in 3 cases. The (10±3)-month follow-up for the 16 patients revealed complete fracture union for all after (12±2) weeks. According to the Majeed scoring at the last follow-up, the pelvic function was evaluated as excellent in 5 cases, as good in 7 cases, and as fair in 4 cases. No such postoperative complications as fracture displacement or internal fixation failure occurred.Conclusion:Owing to the biplane and integrated structure, our self-designed PSOCAP can help reduce the fractures or dislocations around the pubic symphysis to achieve anatomical reduction and strong internal fixation, leading to good clinical efficacy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...